- Stock: In Stock
- Product code: 00-00015585
Battery for the XGRIDS Lixel L3 3D Scanner
The XGRIDS L3 battery is a removable battery for powering the XGRIDS Lixel L3 portable laser 3D scanner. The power source has a capacity of 3350 mAh and a nominal voltage of 14.4 V, is installed directly in the scanner body and is charged using a dedicated charging station. A full charge takes approximately 100 minutes. The battery can be used to replace the main battery or as a spare during long 3D scanning sessions at remote sites.
Advantages of the XGRIDS L3 battery
- Capacity of 3350 mAh. The battery powers the XGRIDS Lixel L3 3D scanner while it collects spatial data. The nominal voltage is 14.4 V.
- Removable design. The power source can be taken out of the scanner for recharging or replacement. It is installed in a dedicated compartment and secured by the housing cover.
- Full charge in approximately 100 minutes. The standard XGRIDS L3 station is used for this. In Charge mode, the battery reaches 100% charge.
- Suitable for long-term storage. The Storage mode of the charging station is intended to prepare the battery for a long period of inactivity. Maintaining an appropriate charge level helps to slow capacity loss.
Compatibility and installation
The battery is designed for the XGRIDS Lixel L3 laser 3D scanner. It fits into the corresponding compartment in the body and connects via the standard contacts.
To install it, you need to:
- Open the cover of the scanner's battery compartment.
- Insert the battery into the corresponding slot.
- Push it all the way to the base of the device.
- Close the cover and check that it is securely fastened.
The removable design allows you to keep a spare power source for replacement when working outdoors.
Charging the XGRIDS L3 battery
To recharge the battery, remove it from the scanner, place it in the standard XGRIDS L3 station and connect the station to the mains power supply.
A full charge of the battery takes approximately 100 minutes. The charging station supports two operating modes:
- Charge mode – full charge. This mode is intended to prepare the battery for use. When the process is complete, the charge level reaches 100%.
- Storage mode – preparation for long-term storage. The station brings the charge to a level suitable for storage and maintains it, which helps to slow capacity loss. For this, the battery must remain in the charging slot and the station must stay connected to the mains.
Monitoring the charge level
During charging, the green indicator on the station shows the current state of the battery.
| Light indication | Battery charge level |
| 1 green flash | 0–24% |
| 2 green flashes | 25–49% |
| 3 green flashes | 50–74% |
| 4 green flashes | 75–99% |
If several batteries are installed, the station charges them one after another. The battery with the highest remaining charge is topped up first, after which the process moves on to the next one.
The standard charging station must be used for the XGRIDS L3. Charging from a power bank or directly via the scanner body is not supported.
Storage and care recommendations
Following the rules for use and storage helps to reduce the loss of battery capacity over its service life.
Main recommendations:
- After each use. Fully charge the battery after you finish working with the scanner.
- During long-term storage. Recharge it at least once every three months.
- When the charge level is low. A discharged or nearly discharged battery must be charged within three days.
- When the scanner is not used for a long time. Switch the station to Storage mode, leave the battery in the corresponding slot and do not disconnect the equipment from the mains.
- For recharging. Use the standard XGRIDS L3 station. Third-party chargers or adapters may damage the battery.
Failure to follow the storage recommendations may cause irreversible damage to the battery. Such faults cannot be repaired and are not covered by the warranty.
Technical specifications
| Parameter | Value |
| Purpose | Powering a portable 3D scanner |
| Compatible equipment | XGRIDS Lixel L3 |
| Capacity | 3350 mAh |
| Nominal voltage | 14.4 V |
| Full charge time | Approximately 100 min |
| Charging method | Via the standard XGRIDS L3 charging station |
| Charging station modes | Charge mode, Storage mode |
| Maximum charge level in Charge mode | 100% |
| Preparation for long-term storage | Via Storage mode |
| Installation | In the scanner's standard battery compartment |
| Design | Removable |
| Charge monitoring | Light indication on the charging station |
Buy the XGRIDS L3 battery to power the XGRIDS Lixel L3 laser 3D scanner during field measurements, surveying work and spatial data collection. Our specialists will help you check equipment compatibility, select a charger and provide recommendations on the use and storage of the battery.